File "cdb2oa.log"
Full Path: /home/analogde/www/WINDOWS/PDK/cdb2oa.log
File size: 2.66 KB
MIME-type: text/plain
Charset: utf-8
********************************************************************************
Program: @(#)$CDS: cdb2oa.exe version 6.1.0 10/10/2006 10:44 (cds126047) $
sub-version IC6.1.0.243
Started at: Sep 28 04:46:43 2009
Hierarchy: /Cadence/IC610
User Name: root
Host Name: localhost.localdomain
Options: -cdslibpath /root/conv_cds.lib -lib gpdk180
Directory: /Cadence/IC610/gpdk180_v3.3/libs.cdb/conv
Log File: /root/cdb2oa.log
Copyright (C) 2001-2005 Cadence Design Systems, Inc. All rights reserved worldwide
********************************************************************************
WARNING (CDBOA-501): The DBUPerUU value defined for view type "maskLayout" in
the library is "2000"; the value in the OpenAccess
technology file ./gpdk180/tech.db is "1000". The translator
has changed the setting in the technology file to "2000" in
order to match the setting in the library.
Warning (Technology Conversion): Layer Metal1 has preferred routing direction 'horizontal', cannot set to 'orthogonal'
Warning (Technology Conversion): Layer Metal2 has preferred routing direction 'vertical', cannot set to 'orthogonal'
Warning (Technology Conversion): Layer Metal3 has preferred routing direction 'horizontal', cannot set to 'orthogonal'
Warning (Technology Conversion): Layer Metal4 has preferred routing direction 'vertical', cannot set to 'orthogonal'
Warning (Technology Conversion): Layer Metal5 has preferred routing direction 'horizontal', cannot set to 'orthogonal'
Warning (Technology Conversion): Layer Metal6 has preferred routing direction 'vertical', cannot set to 'orthogonal'
********************************************************************************
Finished at: Sep 28 04:47:12 2009
45 cells and 236 cellviews were translated from library 'gpdk180' in 28.7s.
Message Summary:
WARNING (CDBOA-501) The { DBUPerUU | user units } value defined for view type
<view_type> in the library is <value>; the value in the
OpenAccess technology file <path> is <value>. The
translator has changed the setting in the technology file
to <value> in order to match the setting in the library.
Generated once. Check that the setting is appropriate. If
required, change the setting manually in OpenAccess or
correct the source database to make the settings consistent
and run the translator again.
********************************************************************************